Menu
Your Cart

Kenika Solar Hybrid Off-Grid Inverter EAF 3000W

Kenika Solar Hybrid Off-Grid Inverter EAF 3000W
Free
Kenika Solar Hybrid Off-Grid Inverter EAF 3000W
  • Stock: In Stock
  • Model: EAF 3000W
  • Weight: 40.00kg
  • Dimensions: 45.50cm x 52.00cm x 28.30cm
190 samples sold
Product Views: 9846

Sistem Off-Grid biasanya dipakai di daerah yang tidak ada jaringan listrik atau energi listriknya kurang. Sistem ini juga bisa digunakan untuk lampu penerangan jalan, lampu taman, dsb. Sistem ini tidak terkoneksi dengan jaringan listrik yang ada. Karena bersifat mandiri, maka diperlukan baterai untuk menyimpan tenaga listrik yang dihasilkan oleh PV (photovoltaic).


Specifications:

MODEL EAF 3000W
PV INPUT
Max. Input Voltage (Voc) 150 Vdc
Optimum Operating Voltage (Vmp) 65 ~ 120 Vdc
Max. Charging Current 65 A
Recommended PV Configuration 3500 W
AC INPUT
AC Input Range (Bypass Mode) 0 ~ 132 Vac / 0 ~ 264 Vac (High-End Limit)
Rated Input Voltage 100 Vac / 110 Vac / 115 Vac / 120 Vac or 200 Vac / 220 Vac / 230 Vac / 240 Vac ± 25%
(2500 W is only for 110 Vac; 3000 W is only for 220 Vac)
Rated Input Frequency 50 Hz / 60 Hz ± 5% / 10% / 15% (Settable)
Max. Charging Current 30 A
INVERTER OUTPUT
Output Voltage 100 Vac / 110 Vac / 115 Vac / 120 Vac ± 2% or 200 Vac / 220 Vac / 230 Vac / 240 Vac ± 2% (Settable)
(2500 W is only for 110 Vac; 3000 W is only for 220 Vac)
Rated Output Power 3000 W
Power Factor 1
Rated Output Frequency 50 Hz / 60 Hz ± 1% (Inverter Mode)
Waveform Sinusoidal
Max. Efficiency (Resistive Load) ≥ 85%
Sleep Mode Settable (< 3% Load) Access in ≤ 2 Min
Output Voltage Harmonic ≤ 3% (Linear Load)
BATTERIES
Battery Voltage 48 Vdc
Battery Type VRLA Battery (Default), GEL / LFP Battery (Optional)
Charging Current 5 ~ 65 A (Settable)
DOD Settable 42 ~ 52.8 Vdc
Default 48 Vdc
EOD Settable 38.4 ~ 48 Vdc
Default 42 Vdc
Equalizing Charge Voltage Settable 55.2 ~ 60 Vdc
Default 56.4 Vdc
Floating Charge Voltage Settable 52.8 ~ 55.2 Vdc
Default 54.5 Vdc
Restoration Point of Overvoltage 62 Vdc
OTHERS
Transfer Time 3 ~ 6 ms (Typical); ≤ 10 ms (Max.)
Overload (Linear Load) 110% for 2 min, 125% for 1 min, 150% for 10 s, 180% for 1 s
ECO Mode (Optional) Load < 3% (Settable), Yes / No Settable
No-Load Shutdown (Optional) Load < 3% ~ 50%, Yes / No Settable
Load Adaptation Inductive Load: ≤ 30%; Capacitive Load: ≤ 50%; Resistive Load: ≤ 100%
Protections Output Overload – Short-Circuit – Overdischarge – Overcharge – Battery Reverse Polarity – PV Reverse Polarity
Lightning Protection Class III
Communications RS232 / USB / RS485; SNMP / Wi-Fi / GPRS (Optional)
Standards IEC62040, IEC / EN 61000
IP Rating IP21
Display LCD & LED
Operating Temperature 0°C ~ 40°C
Relative Humidity ≤ 93%
Noise < 50 dB
Dimensions (W × D × H) (mm) 365.5 × 442 × 210
Packaged Dimensions (W × D × H) (mm) 455 × 520 × 283
Nett Weight (kg) 38.5
Gross Weight (kg) 40

Write a review

Note: HTML is not translated!
Bad Good
Notification Module
This is the sticky Notification module. You can use it for any sticky messages such as cookie notices or special promotions, etc.