Menu
Your Cart

UPS Kenika MS-40KVA 3Phase

UPS Kenika MS-40KVA 3Phase
UPS Kenika MS-40KVA 3Phase
UPS Kenika MS-40KVA 3Phase
UPS Kenika MS-40KVA 3Phase
Free
UPS Kenika MS-40KVA 3Phase
UPS Kenika MS-40KVA 3Phase
UPS Kenika MS-40KVA 3Phase
UPS Kenika MS-40KVA 3Phase
UPS Kenika MS-40KVA 3Phase
  • Stock: In Stock
  • Model: MS-40KVA
  • Weight: 302.00kg
  • Dimensions: 49.00cm x 92.00cm x 125.00cm
190 samples sold
Product Views: 2981

UPS online MS-40KVA menghasilkan tegangan output yang sangat stabil saat terjadi perpindahan dari listrik utama/PLN ke baterai dan mempunyai gelombang sinus murni, sama seperti gelombang listrik yang dihasilkan oleh PLN. Penggunaan UPS MS-40KVA sangat direkomendasikan untuk beban yang sensitif seperti peralatan laboratorium, peralatan kedokteran, komputer server atau beban sensitif lainnya.

UPS MS-40KVA memiliki fitur ECO Mode yang memberikan efek hemat energi serta memiliki proteksi terhadap pengisian berlebih, pelepasan daya berlebih, korsleting, beban berlebih, dan proteksi lonjakan arus listrik.

*Baterai yang digunakan 30Pcs 12V 24Ah
*Size Casing Battery Bank C-12 setelah dirakit 470×1190×780 mm (4 Susun/Layer).


FEATURES:

  1. Online double-conversion with full DSP control
  2. IGBT inverter with output isolation transformer
  3. 100% unbalance load capability
  4. Output power factor 0.9
  5. Generator compatible
  6. Support battery cold start and auto-restart when mains power is restored
  7. ECO mode operation for energy saving
  8. Superior protection
  9. 5.7 inches LCD touchscreen, friendly human and machine interface
  10. Intelligent self-diagnosing function, all-kinds of failure protection, large capibility of history records storage
  11. High MTBF (>200,000h)
  12. Low MTTR (<0.5h)
  13. Standard Emergency Power Off (EPO)


Specifications:

MODEL MS-40KVA
Phase 3-Phase In/3-Phase Out
Capacity 40kVA/36kW
INPUT
Rated Voltage 380Vac
Voltage Range ±25%
Rated Frequency 50/60Hz
Frequency Range 50/60Hz ± 5Hz
Power Factor ≥ 0.95 (with Filter)
Bypass Voltage Range ±20%
Delayed Start of Rectifier 1~300s (Settable via Display Panel)
ECO Voltage Range ±10%
OUTPUT
Voltage 380Vac
Voltage Regulation ±1%
Frequency Synchronized with utility in mains mode; 50/60Hz ± 0.1% battery mode
Waveform Sinusoidal
Power Factor 0.9
Crest Factor 3:1
Total Harmonic Distortion (THDV) ≤ 2% (Linear Load); ≤ 5% (Non-Linear Load)
Transfer Time AC Mode to Battery Mode: 0ms
Inverter Mode to Bypass Mode: 0ms
Inverter Mode to ECO Mode: 5~10ms
Overload 105%: Long Time Running, 105% ~ 110% for 1h, 110% ~ 125% for 10 min, 125% ~ 150% for 1 min, 150% ~ 200% for 200ms, >200% for 100ms
Slight Adjusment of Inverter Output Voltage ±5V
BATTERIES
DC Voltage 12V 24Ah
Number of Battery 30pcs
Battery Voltage 360VDC
Charging Current 10A
Charging Three-Stage Charging, Auto Switch Floating/Equalizing Charge
Battery State Display Display Battery Backup Time, Battery Remaining Capacity
Battery Self-Test Settable Periodic Self-Test; Manually Configurable Test Time and Voltage
SYSTEM
Efficiency In Line Mode: Max. 93%; ECO Mode: ≥98%
Max. Parallel Number 6
Protections Short-Circuit, Overload, Over-Voltage, Under-Voltage, Low Battery, Over Temperature, Fan Fault
Communications RS232/RS485/Dry Contacts (Standard), SNMP (Optional)
IP Rating IP20
EMI EN62040-2
EMS IEC61000-4-2 (ESD)
IEC61000-4-3 (RS)
IEC61000-4-4 (EFT)
IEC61000-4-5 (Surge)
OTHERS
Humidity 0~95% RH @ 0~40°C (Non-Condensing)
Noise Level 55dB
UPS Dimension (D×W×H) 435×865×1125 mm
Package Dimension (D×W×H) 490×920×1250 mm
Nett Weight (UPS Only) 260 kg
Gross Weight (UPS Only) 302 kg

Write a review

Note: HTML is not translated!
Bad Good
Notification Module